Skip to content

Define RSSI value: Specify a value between -110 dBm and 0 dBm (0 dBm disables the RSSI filter).

Inversion mode :

  • Not enabled: The reader only detects tags with a signal greater than or equal to the specified value.
  • Enabled: Only tags with a signal less than or equal to the specified value are detected.

Example: If the RSSI filter is set to -49 dBm with inversion disabled, a tag with an RSSI of -20 dBm will be detected, while a tag with an RSSI of -60 dBm will not.